Floor size: The floor portion of the arena is a standard NHL hockey rink 200ft. X 85ft; the 42 in. high (concrete to cap rail) dasher boards can only be removed at the bottom of each isle, and there is no retractable seating.

Fire Aisles: 6ft on concourse; 4ft. Minimum on the floor seating.


Over 1500 padded, cloth upholstered folding chairs are available for floor seating.


Standard stage setup is 40 ft. deep X 60 ft. wide X 4 ft. tall, 8 ft. wide X 24 ft. deep sound wings SL & SR, and a front of house mixer riser 12 ft. deep X 16 ft. wide X 1ft. tall - 100 ft. from the down stage edge. Maximum stage setup is 48 ft. deep X 68 ft. wide X 4ft. tall, 16 ft. wide by 24 ft. deep sound wings SR & SL, and a front of the house mixer riser 16 ft. deep X 24 ft. wide X 1 ft. tall, 100 ft. from the down stage edge. All stage equipment is manufactured by StageRight and stage decks bridge between supports.

The Arena also has one ADA compliant handicap ramp, 3 portable rolling stairs capable of clamping to a stage from 4 ft. to 6 ft. in height.


20 barricades each 4 ft. wide and 50 bike racks.


The 5,000 lb. capacity freight elevator is located in the North East corner of the loading dock, 60 ft. from the upstage left corner. This elevator has a 4 ft. wide by 7 ft. tall opening, a depth of 8 ft. 4 in. and travels from the loading docks to the concourse to the northeast spotlight location.


There is a passenger elevator located next to the east entrance on the rink level, which travels to the main lobby, concourse and the southeast spotlight location. This elevator has a 3500 lb. capacity, a 3.ft 6 in. wide by 7. ft tall opening, and a 5.ft by 6.ft 10 in. wide cab.


The arena has three loading docks, the two main loading docks are located in the North East corner of the building, 60ft from the stage left vomitory. They are 9ft. 5 in. wide by 11 ft. 3 in. tall and are 4 ft. high off the street level, each with a hydraulic dock leveler ramp capable of adjusting from 3 ft. 4 in. to 6 ft. 8 in. from street level.

The third loading dock opens into the Public Skate Lobby and is located next to the east entrance, 60ft from the front of house vomitory. This entrance is 9 ft. 5 in. wide by 9 ft. 6 in. high and is at street level.


Stage left vomitory, also known as the Zamboni tunnel, is 10ft. wide and 11.ft 3 in. tall and is located at the opposite end of the loading dock from the roll up garage doors and below Section V in the bowl.

Front of house vomitory, also know as the visiting team's entrance, is 7 ft. 10 in. wide by 9 ft. 6 in. tall and is located on the opposite end of the Public Skate Lobby from the street level loading dock and below Section D in the bowl.


The arena had one propane powered Caterpillar model GC30, with a maximum load capacity of 6,000 lbs. and a max height of 14 ft.


One electric Zamboni model 522

One propane Zamboni model 500

One gasoline powered Zamboni edger


The Tsongas Arena has a state of the art HVAC system that creates a comfortable environment for fans whether it is 40 below in February or hot and humid in August. The rink environment is closely monitored for air quality according to Commonwealth of Massachusetts Health Regulations and has never failed the "Requirements To Maintain Air Quality In indoor Skating Rinks" State Sanitary Code, Chapter XI.


The house lights controls are located 25 ft. from the upstage left side next to the operations department office and in Press Box A. Arena bowl lighting consists of 36 overhead 1000W Metal Halide floodlights and 120 sideline 1000W Metal Halide floodlights.


There are 6 spot light locations around the arena, each with both a 208 volt 20 amp outlet and a 120 volt 20 amp outlet. The arena has four 1290 XLT long throw 2 kW Xenon Lycian follow spots.


Event power room is located 75 ft. from the upstage left corner where all services are on one transformer. In this room we have 3 Cam Lock accessible circuits:

Motors: 400 amps fed from DP-21-N/E 120/208 3 phase 4 wire plus ground.

Sound: 400 amps fed from DP-21-N/E 120/208 3 phase 4 wire plus ground.

Lighting: 400 amps fed from DP-21-N/E 120/208 3 Phase 4 wire plus ground.

Front of House Power is located in the southwest corner of the floor:

One 100 Amp. 120/208 Singe Phase with Neutrals and Ground. 

One 200 Amp. Three Phase with Neutrals and Ground.

Outside satellite panel located on the front of the building in the southwest corner:

One 100 Amp. 120/208 Singe Phase with Neutrals and Ground. 

One 200 Amp. Three Phase with Neutrals and Ground.

Outside Shore Power located on the northeast side of the building accessible from the east parking lot.

One 100 Amp. 120/208 Singe Phase with Neutrals and Ground. 

One 200 Amp. Three Phase with Neutrals and Ground.

On the concourse in each of the 19 niches (sections D through V) there are two 20A/120V and one 20a/230V outlets. In each of the Press Boxes (W,X,A,B,C) there are two 20A/120V outlets and 4 phone lines.


Pyrotechnics are allowed, but the Lowell Fire Department requires a demonstration, permit and an additional Fireman on duty.

Contact:  Capt. John Weber at 978-459-5554


Fog and smoke effects are allowed but you must contact the Lowell Fire Department and notify them of what kind of effects you are planning on using in the arena.  The Lowell Fire Department requires an additional Fireman on duty for all special effects.


There are no catwalks or fall suppression system anywhere in the arena: steel is accessible by a rented 66 ft. boom lift.

Height: 
Floor to low steel is 51 ft.
Floor to high steel is 67 ft.

Trusses: 
16 ft. high

Rigging load per beam using a dead hang = 4000 lbs.

Rigging load per beam using a 45o bridal = 2500 lbs.

There are only four types of rigging beams in the building super structure; these are types A.B.C. and D (see diagram on next page).

No rigging will be allowed on any other beam, truss, pipe, or other structural member.

All rigging loads should be suspended by cables across the top flange of the rigging beams with a burlap cloth between beam and cable to protect beam paint.

Beam clamps, which are attached to one side of the bottom flange of beams will not be permitted.

After rigging is complete the rigging boom lift must exit the floor from the stage left vomitory. Whatever the stage width is, at least 12 ft. between the stage left side and the dasher boards must be left clear, during load-in, for the lift to exit. The boom lift is always parked in the loading dock area. The remaining portion of the stage left side would be built immediately upon the lift’s exit, After the event, as soon as the stage left portion of the stage is cleared of equipment. That part of the stage left side of the stage will be broken down to allow the lift to reenter the floor for de-rigging.


Main Cluster Speaker Assembly: 6 EAW JR569 speakers

Fill Cluster Speaker Assembly: 6 EAW JR609 speakers

Over Rink Speakers: 4 EAW ASR3931 speakers


Nearest water sources is 25 ft. from the stage left.

No helium balloons are allowed in the arena, if during an event balloons become stuck to the ceiling there will be assessed an expensive labor charge for their removal from the ceiling.

There are no union or building curfews.

There is one ATM and two payphones located in the main lobby. There is also one payphone near the East Entrance, loading dock area and two on the arena’s concourse.

Vending machines are located near the East Entrance.

 

 

 

 


© 2000 All rights reserved

webmaster@paultsongasarena.com

 

Tsongas Arena
300 Martin Luther King Jr. Way
Lowell, MA 01852

PH: (978) 848-6900
FX: (978) 848-6999

 

 

site by Pixel Point