Click
here for seating
charts.
Floor
size: The floor
portion of the arena is
a standard NHL hockey
rink 200ft. X 85ft; the
42 in. high (concrete to
cap rail) dasher boards
can only be removed at
the bottom of each isle,
and there is no
retractable seating.
Fire
Aisles: 6ft on
concourse; 4ft. Minimum
on the floor seating. |


|
Over
1500 padded, cloth
upholstered folding
chairs are available for
floor seating. |


|
Standard
stage setup is 40 ft. deep
X 60 ft. wide X 4 ft.
tall, 8 ft. wide X 24 ft.
deep sound wings SL
& SR, and a front of
house mixer riser 12 ft.
deep X 16 ft. wide X
1ft. tall - 100 ft. from the
down stage edge. Maximum
stage setup is 48 ft.
deep X 68 ft. wide X 4ft.
tall, 16 ft. wide by 24 ft. deep
sound wings SR & SL,
and a front of the house
mixer riser 16 ft. deep
X 24 ft. wide X 1 ft.
tall, 100 ft. from the
down stage edge. All
stage equipment is
manufactured by
StageRight and stage
decks bridge between
supports.
The
Arena also has one ADA
compliant handicap ramp,
3 portable rolling
stairs capable of
clamping to a stage from
4 ft. to 6 ft. in
height.
|


|
20
barricades each 4 ft.
wide and 50 bike racks. |


|
The
5,000 lb. capacity
freight elevator is
located in the North
East corner of the
loading dock, 60 ft.
from the upstage left
corner. This elevator
has a 4 ft. wide by 7
ft. tall opening, a
depth of 8 ft. 4 in. and
travels from the loading
docks to the concourse
to the northeast
spotlight location. |


|
There
is a passenger elevator
located next to the east
entrance on the rink
level, which travels to
the main lobby,
concourse and the
southeast spotlight
location. This elevator
has a 3500 lb. capacity,
a 3.ft 6 in. wide by 7.
ft tall opening, and a
5.ft by 6.ft 10 in. wide
cab. |


|
The
arena has three loading
docks, the two main
loading docks are
located in the North
East corner of the
building, 60ft from the
stage left vomitory.
They are 9ft. 5 in. wide
by 11 ft. 3 in. tall and
are 4 ft. high off the
street level, each with
a hydraulic dock leveler
ramp capable of
adjusting from 3 ft. 4
in. to 6 ft. 8 in. from
street level.
The
third loading dock opens
into the Public Skate
Lobby and is located
next to the east
entrance, 60ft from the
front of house vomitory.
This entrance is 9 ft. 5
in. wide by 9 ft. 6 in.
high and is at street
level.
|


|
Stage
left vomitory, also
known as the Zamboni
tunnel, is 10ft. wide
and 11.ft 3 in. tall and
is located at the
opposite end of the
loading dock from the
roll up garage doors and
below Section V in the
bowl.
Front
of house vomitory, also
know as the visiting
team's entrance, is 7
ft. 10 in. wide by 9 ft.
6 in. tall and is
located on the opposite
end of the Public Skate
Lobby from the street
level loading dock and
below Section D in the
bowl.
|


|
The
arena had one propane
powered Caterpillar
model GC30, with a
maximum load capacity of
6,000 lbs. and a max
height of 14 ft. |


|
One
electric Zamboni model
522
One
propane Zamboni model
500
One
gasoline powered Zamboni
edger
|


|
The
Tsongas Arena has a
state of the art HVAC
system that creates a
comfortable environment
for fans whether it is
40 below in February or hot and
humid in August. The rink
environment is closely
monitored for air
quality according to
Commonwealth of
Massachusetts Health
Regulations and has
never failed the
"Requirements To
Maintain Air Quality In
indoor Skating
Rinks" State
Sanitary Code, Chapter
XI. |


|
The
house lights controls
are located 25 ft. from
the upstage left side
next to the operations
department office and in
Press Box A. Arena bowl
lighting consists of 36
overhead 1000W Metal
Halide floodlights and
120 sideline 1000W Metal
Halide floodlights. |


|
There
are 6 spot light
locations around the
arena, each with both a
208 volt 20 amp outlet
and a 120 volt 20 amp
outlet. The arena has
four 1290 XLT long throw
2 kW Xenon Lycian follow
spots.
|


|
Event
power room is located 75
ft. from the upstage
left corner where all
services are on one
transformer. In this
room we have 3 Cam Lock
accessible circuits:
Motors:
400 amps fed
from DP-21-N/E
120/208 3 phase 4
wire plus ground.
Sound:
400 amps fed
from DP-21-N/E
120/208 3 phase 4
wire plus ground.
Lighting:
400 amps fed from
DP-21-N/E 120/208 3
Phase 4 wire plus
ground.
Front
of House Power is
located in the southwest
corner of the floor:
One
100 Amp. 120/208
Singe Phase with
Neutrals and
Ground.
One
200 Amp. Three Phase
with Neutrals and
Ground.
Outside
satellite panel located
on the front of the
building in the
southwest corner:
One
100 Amp. 120/208
Singe Phase with
Neutrals and
Ground.
One
200 Amp. Three Phase
with Neutrals and
Ground.
Outside
Shore Power located on
the northeast side of
the building accessible
from the east parking
lot.
One
100 Amp. 120/208
Singe Phase with
Neutrals and
Ground.
One
200 Amp. Three Phase
with Neutrals and
Ground.
On
the concourse in each of
the 19 niches (sections
D through V) there are
two 20A/120V and one
20a/230V outlets. In
each of the Press Boxes
(W,X,A,B,C) there are
two 20A/120V outlets and
4 phone lines.
|


|
Pyrotechnics
are allowed, but the
Lowell Fire Department
requires a demonstration,
permit and an additional
Fireman on duty.
Contact:
Capt. John Weber at
978-459-5554
|


|
Fog
and smoke effects are
allowed but you must
contact the Lowell Fire
Department and notify
them of what kind of
effects you are planning
on using in the arena.
The Lowell Fire
Department requires an
additional Fireman on
duty for all special
effects. |


|
There
are no catwalks or fall
suppression system
anywhere in the arena:
steel is accessible by a
rented 66 ft. boom lift.
Height:
Floor to low
steel is 51 ft.
Floor to high steel
is 67 ft.
Trusses:
16 ft. high
Rigging
load per beam using a
dead hang = 4000 lbs.
Rigging
load per beam using a 45o
bridal = 2500 lbs.
There
are only four types of
rigging beams in the
building super
structure; these are
types A.B.C. and D (see
diagram on next page).
No
rigging will be allowed
on any other beam,
truss, pipe, or other
structural member.
All
rigging loads should be
suspended by cables
across the top flange
of the rigging beams
with a burlap cloth
between beam and cable
to protect beam paint.
Beam
clamps, which are attached to one
side of the bottom flange of
beams will not be
permitted.
After
rigging is complete the
rigging boom lift must
exit the floor from the
stage left vomitory.
Whatever the stage width
is, at least 12 ft.
between the stage left
side and the dasher
boards must be left
clear, during load-in,
for the lift to exit.
The boom lift is always
parked in the loading
dock area. The remaining
portion of the stage
left side would be built
immediately upon the
lift’s exit, After the
event, as soon as the
stage left portion of
the stage is cleared of
equipment. That part of
the stage left side of
the stage will be broken
down to allow the lift
to reenter the floor for
de-rigging.
|


|
Main
Cluster Speaker
Assembly: 6 EAW
JR569 speakers
Fill
Cluster Speaker Assembly:
6 EAW JR609 speakers
Over
Rink Speakers: 4 EAW
ASR3931 speakers
|


|
Nearest
water sources is 25 ft.
from the stage left.
No
helium balloons are
allowed in the arena, if
during an event balloons
become stuck to the
ceiling there will be
assessed an expensive
labor charge for their
removal from the
ceiling.
There
are no union or building
curfews.
There
is one ATM and two
payphones located in the
main lobby. There is
also one payphone near
the East Entrance,
loading dock area and
two on the arena’s
concourse.
Vending
machines are located
near the East Entrance. |
|

|
|
 |
 |
 |
|
|